Products
ULTRA LOW LOSS-03 (ULL03)
Ultra Low Loss ULL03 Cable 0.25 dB/feet @18GHz Phase Stable with temperature
Triple-Shielded, better than-90dB shielding
APPLICATIONS
Radars, EW Systems for lowest loss and phase stability. Conform to airborne needs of temp. cycling, vibration etc. Applications needing ultra phase stable cables
Test cables for Hi-Vacuum chambers FEATURES
Ultra Low Loss in DC~18 GHz range (much lower loss than solid PTFE dielectric cable) Loss, VSWR & Phase are stable with bending
High temperature dielectric & jacketing for harsh environment application (up to + 150C) Superior Shielding Effectiveness over-90 dB
EQUIVALENT TO: H&S Sucoflex 106 Microcoax UFB311A Radiall SHF8M • • Semflex LA290
Attenuation and Power Handling Data
|
Frequency |
Insertion Loss |
Av Power Watts |
|
|
dB/100ft |
dB/100m |
||
|
500 MHz |
3.7 |
12.1 |
2400 |
|
1 GHz |
5.2 |
17.0 |
1700 |
|
2 GHz |
7.5 |
24.5 |
1200 |
|
4 GHz |
10.7 |
35.1 |
820 |
|
6 GHz |
13.3 |
43.8 |
660 |
|
10 GHz |
18.1 |
59.3 |
500 |
|
12 GHz |
19.3 |
63.4 |
450 |
|
16 GHz |
22.7 |
74.3 |
380 |
|
18 GHz |
24.2 |
79.2 |
360 |
Physical and Mechanical Specification
|
Dimensions |
inches |
mm |
|
Jacket |
0.335 |
8.5 |
|
Min. Bending Radius |
1.7 |
45 |
|
Weight |
0.184 Kg/m |
|
|
Temperature Range |
|
|
|
Electrical Specifications |
||
|
Impedance |
50 ohms |
|
|
Velocity of Propagation |
> 80 % |
|
|
Shielding Effectiveness |
better than -90dB |
|
|
Capacitance |
24.5 pF/foot |
|
|
Cut-off Frequency |
18 GHz |
|
Connectors Specifications
|
Specifications |
SMA Connectors |
N Connectors |
TNC Connectors |
|
Outer Conductor |
Stainless Steel, Passivated |
Stainless Steel, Passivated |
Stainless Steel, Passivated |
|
Center Conductor |
BeCu, Gold Plated |
BeCu, Gold Plated |
BeCu, Gold Plated |
|
Insulation |
PTFE |
PTFE |
PTFE |
|
Gaskets |
Silicone Rubber |
Silicone Rubber |
Silicone Rubber |
|
Nominal Impedance |
50 |
50 |
50 |
|
Frequency range |
DC~18 GHz |
DC~18 GHz |
DC~18 GHz |
|
Mating & Unmating |
500 Operations min |
500 Operations min |
500 Operations min |
|
Vibration |
As per MIL-STD202, method 204, test condition D |
||
|
Mechanical Shock |
As per MIL-STD202, method 213, test condition I |
||
|
Thermal Shock |
As per MIL-STD202, method 107, test condition B |
||
|
Corrosion |
As per MIL-STD202, method 101, test condition B |
||
|
Humidity |
As per MIL-STD202, method 106 |
||
|
Temperature Cycle |
As per MIL-STD202, method 102A, test condition C |
||